Restoring Pipe, Inside And Out

Market
Power & Utilities

Challenge
Leaks had been discovered in a circulating water system. The points of concern were in prestressed concrete cylinder pipe and steel pipe in sizes ranging from 92” to 138” in diameter. Internally, there were signs of spalling and at one joint portions of the steel bell had become exposed.

Engineered Solution
HydraTite internal pipe joint seals were chosen to remedy the joints with interior damage and the HydraWrap Structural Composite Repair System was to be applied on the exterior of the compromised joints.

Scope
The interior surface was prepared ensuring a uniform and smooth surface for sealing before the arrival of the four HydraTech technicians. Inside the pipe at a 45-degree elbow, scaffolding was set up and grout was used to fill two joints. The double-wide HydraTite rubber seal was positioned over each joint and the three retaining bands locked the seals in place. The actual installation of the 108” and 120” seals took roughly two hours each. Finally, the seals were air tested. Over the next two days, the HydraWrap was applied to the exterior of seven joints. Exposed reinforcement bars were cut away and loose concrete was removed. Then the exterior surface of these joints was pressure washed. Hydraulic cement was then applied to the joint to restore the surface profile, creating a smooth transition from one pipe to another. Epoxy was applied to the exterior of the joints, the carbon fiber fabric was saturated in wet-out epoxy and then two layers were applied to the exterior of the joints. Four of the 92” joints, two of the 124” joints, and one 138” joint were wrapped.

Four images, pipe joint that has become offset and separated, HydraTite applied onto the interior surface of the pipe, HydraTite installed over a joint, close-up of HydraTite over a joint

Solution
In three days a crew of four was able to eliminate leaks during the shut-down window and restore this system at a fraction of what replacement would have cost. These joints will be protected for a lifetime.

pipeline sealing solutions
pipeline sealing solutions
pipeline sealing solutions
trenchless pipe repair
trenchless pipe repair
pipeline sealing solutions
pipeline sealing solutions
water pipe corrosion
pipeline sealing solutions
pipeline sealing solutions
water pipe corrosion
trenchless pipe repair

Magnifying glass logo Explore HydraTite

More information logo, negative plus sign More Products

Arrow bending back on itself to represent going back Case Studies

Magnifying glass logo
Explore HydraTite

More information logo, negative plus sign
More Products

Arrow bending back on itself to represent going back
Case Studies

Magnifying glass logo
Explore HydraTite

More information logo, negative plus sign
More Products

Arrow bending back on itself to represent going back
Case Studies

power plant pipeline repair

OUR PRODUCTS

Trenchless Repairs Custom Made

industrial pipe resotration

OUR INDUSTRIES

From Power to Water We Have It Covered

marine pipe sealing

OUR RESOURCES

Technical Data Sheets and Product Literature